您现在的位置:首页 > 技术文章 > Honeywell霍尼韦尔MIDAS四合一探测器 Hi-Tech Products Midas-M (4 in 1)

Honeywell霍尼韦尔MIDAS四合一探测器 Hi-Tech Products Midas-M (4 in 1)

  • 更新时间:2026-01-21      浏览次数:29
    • Honeywell霍尼韦尔MIDAS四合一探测器 2020新款 Hi-Tech Products  Midas-M (4 in 1)
      Hi-Tech Products  Midas-M (4 in 1)

      Hi-Tech Products over view
      Midas-M (4 in 1)
      Vertex and Vertex SF

      MIDAS-M AT A GLANCE

      Delivering lower cost of ownership • Significantly lower cost in Max 4 gases on the single transmitter (Transmitter, Tubing, Wiring) • Small footprint (1/4 space to replace 4 transmitters) Enhanced Safety Tolerance • Reflex • Alarm Voting (2020 Q2) • Alarm Verif-I (2020 Q2) • LIT (2020 Q3)

      Advanced UI in HMI and Web page


      PRODUCT OVERVIEW
      •Fixed 4-gas extractive gas detector for single point detecting •Lower cost per detecting point with multi-sensor cartridge •Easy to use and maintain by modularized design


      OVERALL STRUCTURE


      MIDAS-M FEATURES
      •Extractive multi-gas transmitter (up to 4 gases)
      •Modular serviceable pump
      •Hot swap smart sensor cartridge
      •Serviceable smart sensor
      •24 VDC or 48V VDC PoE(IEEE 802.3af compliant)
      •Remote access on internet browser via Ethernet
      •Modbus/TCP •3 relays in Transmitter and Optional 9 relays
      •VERIF-I (2020 Q2) •LIT(2020 Q3)
      •3 wire sink, 3 wire source, or 4 wire fully isolated 021mA for each channel •14 AWG  and CAT5
      •0°C to +40°C (32°F to 104°F)
      •EN50270:2015, UL 61010-2012
      •Wall mounted

      MIDAS-M SET UP OPTIONS


      MIDAS-M SET UP OPTIONS
      Midas Key Applications
      •Pyrolyzer
      •Gas Cabinet (stand alone)
      •Chemical Mixer
      •Ambient

      Midas-M Key Applications
      •Exhaust (Scrubber)
      •Production Tool (CVD, Dry Etch)
      •VMB
      •Ambient


      USER INTERFACE-DISPLAY


      DISPLAY ACCORDING TO THE STATUS

      ▪ Gas name display
      ▪ Fault message display
      ▪ Alarm LED is turned on if at least one channel is in alarm
      ▪ Fault LED is turned on if there is fault
      ▪ LCD backlight is turned on depending on the channel status and device status


      USER INTERFACE
      Usage: Provides gas detection and alarm setting function for each channel 
      Function details:
      1.Channel: Set the desired channel
      2.Gas: Set the gas you want to detect on each channel. Gas-name and K-factor (weight value for gas value) can be set only for User-gas.
      3.Range: Measurable range. Can not be set.
      4.Alarm1: Sets the concentration at which Alarm1 occurs.
      5.Alarm2: Sets the concentration at which Alarm2 occurs.
      6.Dead band: Dead band setting
      7.Alarm delay: When an alarm condition is reached, an alarm occurs at dealytime
      8.Latching alarms: Set up Latching in an alarm situation
      9.Calibration period: Set the period of time for calibrating the progress alarm.
      10.Reset to default: Changes the setting value to factory default.
      11.Reset: Returns the setting value to the previous setting value.


      TRANSMITTER TERMINALS

      WIRING RELAY MODULE

      MIDAS-M SMART SENSOR CARTRIDGE

      MIDAS-M_SMART SENSOR AVAILABLE AT LAUNCH
      Part number  Description
      MMS-00 Midas-M Dummy Sensor
      MMS-E2 Midas-M Hydrogen Chloride (HCI) 0 - 8ppm, 2 years
      MMS-X2 Midas-M Silane (SiH4) 0 -20 ppm, 2 years
      MMS-G2 Midas-M Hydrogen (H2) 0 - 1000ppm, 2 years
      MMS-L2 Midas-M Chlorine (CI2) 0 - 2ppm, 2 years
      MMS-A2 Midas-M Ammonia (NH3) 0 - 100ppm, 2 years
      MMS-C2 Midas-M Carbon Monoxide (CO) 0 - 100ppm, 2 years
      MMS-R2 Midas-M Phosphine (PH3) 0 - 1200ppb, 2 years
      MMS-U2 Midas-M Ozone (O3) 0 - 0.4ppm, 2 years
      MMS-D2 Midas-M Oxygen (O2) 0 - 25%v/v, 3 years
      MMS-S2 Midas-M Sulphur Dioxide (SO2) 0 - 8ppm, 2 years
      MMS-Z2 Midas-M Hydrogen Flouride (HF) 0 - 12ppm, 2 years


      MIDAS-M_SMART SENSOR AVAILABLE AFTER LAUNCH


      Release Plan        MIDAS-M Catridge                 Gas Name
      Available 1 Quarter later  MMS-Z3/Z4  HF
      Available 1 Quarter later  MMS-Z3/Z4  BF3
      Available 1 Quarter later MMS-Z3/Z4  WF6
      Available 1 Quarter later MMS-TR1/TR2 CO2
      Available 2 Quarters later MMS-ET1/ET2 ETO
      Available 2 Quarters later MMS-ET1/ET2 TEOS
      Available 2 Quarters later MMS-K1/K2 AsH3
      Available 2 Quarters later MMS-K1/K2 GeH4
      Available 3 Quarters later MMS-Q1/Q2 Br2
      Available 3 Quarters later MMS-Q1/Q2 ClO2
      TBD MMS-Q1/Q2 ClF3
      Available 4 Quarters later MMS-P1/P2 B2H6
      Available 4 Quarters later MMS-T1/T2 CO2
      Available 4 Quarters later MMS-V1/V2 NO
      Available 4 Quarters later MMS-V21/V22 NO2
      Available 5 Quarters later MMS-H3/H4 H2S TBD POCl3
      Available 5 Quarters later MMS-Y1/Y2 HCN
      Available 5 Quarters later MMS-X1/X2 H2Se


      GAS TABLE
      ORDER INFORMATION- TRANSMITTER
      MIDA M Extractive Transmitter for Universal Gas Detection
      Part number    Description
      MMT-01      MIDAS-M  4-20mA Extractive Transmitter
      MMT-02      MIDAS-M  TCP/IP Modbus Extractive Transmitter
      MMT-T01    MIDAS-M  4-20mA Extractive Transmitter with Tube
      MMT-T02    MIDAS-M  TCP/IP Modbus Extractive Transmitter  with Tube
      MMT-B01    MIDAS-M  4-20mA Extractive Transmitter Bulk Package(6pcs)
      MMT-B02    MIDAS-M  TCP/IP Modbus Extractive Transmitter Bulk Package(6pcs)
       
      OPTION and Spares
      MM-REL Midas-M Relay Module
      MM-PM   Midas-M Relay Module
      MM-FIL  Midas-M Relay Module
      MM-B01  Midas-M 4-20mA Base Module
      MM-B02  Midas-M  TCP/IP Base Module
      MM-M01  Midas-M 4-20mA Main Module
      MM-M02  Midas-M  TCP/IP Main Module